Selection of current density under the brushes in DC machines.

  • В П Толкунов
  • В Н Брацлавский
  • З М Осетрова
  • В У Пронин

Abstract

The results of the study of machines with a higher current density under the brushes are considered. It is shown that in a number of cases it is advisable to increase the current density under the brushes to 16-18 A / cm ^ 2.

Published
2019-02-07
Section
Automated Electromechanical Systems