Determination of the maximum temperature of the stator winding of an integrated asynchronous motor.

  • Г. И. Шевчук
  • Б. И. Слободниченко

Abstract

A method is proposed for determining the maximum temperature of the stator winding of an integrated asynchronous electric motor with an axial cooling system. Simple relations have been obtained, allowing to calculate the maximum overheating of the stator winding of the built-in asynchronous motor of the refrigerating compressor.

Published
2019-02-24
Section
Automated Electromechanical Systems