Calculation of additional losses in the traction motor when powering the thyristor-pulse converter.
Abstract
A method for calculating the additional losses in a direct current dc motor when powered from a thyristor-pulse converter in a wide switching frequency range is proposed. An experimental study of the magnitude of the additional losses is performed as a function of the main parameters of the switching power mode.